Shell and Tube Heat Exchangers are precision-engineered thermal transfer systems designed for industrial process cooling, heating, and energy recovery. Featuring a robust shell body and high-efficiency tube bundle, this equipment provides reliable and continuous operation under high temperature and pressure conditions.
Technical Parameters
Heat duty: customized per process
Pressure: up to 10 MPa
Temperature: up to 500°C
Tube diameter: 10–38 mm (custom available)
Tube material: carbon steel / stainless steel / copper-nickel / titanium
Standards: Designed to international industrial standards (ASME, ISO)
Shell and Tube Heat Exchangers are precision-engineered thermal transfer systems designed for industrial process cooling, heating, and energy recovery. Featuring a robust shell body and high-efficiency tube bundle, this equipment provides reliable and continuous operation under high temperature and pressure conditions.
Technical Parameters
Heat duty: customized per process
Pressure: up to 10 MPa
Temperature: up to 500°C
Tube diameter: 10–38 mm (custom available)
Tube material: carbon steel / stainless steel / copper-nickel / titanium
Standards: Designed to international industrial standards (ASME, ISO)
Technical Data(Heat transfer tube Φ20)
|
Nominal diameter(mm) |
Number of tube passes |
Number of tube |
Center row tube number |
Tube side flow area |
Heat transfer area |
||||
|
|
|
|
|
|
1500 |
2000 |
3000 |
4500 |
6000 |
|
159 |
1 |
15 |
5 |
0.0030 |
1.4 |
1.9 |
2.8 |
|
|
|
219 |
1 |
33 |
7 |
0.0066 |
3.1 |
4.1 |
6.2 |
|
|
|
273 |
1 |
65 |
9 |
0.0131 |
6.1 |
8.2 |
12.3 |
18.4 |
24.5 |
|
|
2 |
56 |
8 |
0.0056 |
5.3 |
7.0 |
10.6 |
15.8 |
21.1 |
|
325 |
1 |
99 |
11 |
0.0199 |
9.3 |
12.4 |
18.7 |
28.0 |
37.3 |
|
|
2 |
88 |
10 |
0.0088 |
8.3 |
11.1 |
16.6 |
24.9 |
33.2 |
|
|
4 |
68 |
11 |
0.0034 |
6.4 |
8.5 |
12.8 |
19.2 |
25.6 |
|
400 |
1 |
174 |
14 |
0.0350 |
16.4 |
21.9 |
32.8 |
49.2 |
65.6 |
|
|
2 |
164 |
15 |
0.0165 |
15.5 |
20.6 |
30.9 |
46.4 |
61.8 |
|
|
4 |
146 |
14 |
0.0073 |
13.8 |
18.3 |
27.5 |
41.3 |
55.0 |
|
450 |
1 |
220 |
17 |
0.0477 |
22.3 |
29.8 |
44.7 |
67.0 |
89.3 |
|
|
2 |
220 |
16 |
0..0221 |
20.7 |
27.6 |
41.5 |
62.2 |
82.9 |
|
|
4 |
200 |
16 |
0.0101 |
18.8 |
25.1 |
37.7 |
56.5 |
75.4 |
|
500 |
1 |
275 |
19 |
0.0553 |
|
34.6 |
51.8 |
77.8 |
103.7 |
|
|
2 |
256 |
18 |
0.0257 |
|
32.2 |
48.3 |
72.4 |
96.5 |
|
|
4 |
222 |
18 |
0.0112 |
|
27.9 |
41.8 |
62.8 |
83.7 |
Technical Data(Heat transfer tube Φ25)
|
Nominal diameter(mm) |
Number of tube passes |
Number of tube |
Center row tube number |
Tube side flow area |
Heat transfer area |
||||
|
|
|
|
|
|
1500 |
2000 |
3000 |
4500 |
6000 |
|
159 |
1 |
11 |
3 |
0.0038 |
1.3 |
1.7 |
2.6 |
|
|
|
219 |
1 |
25 |
5 |
0.0087 |
2.9 |
3.9 |
5.9 |
|
|
|
273 |
1 |
38 |
6 |
0.0132 |
4.5 |
6.0 |
9.0 |
13.4 |
17.9 |
|
|
2 |
32 |
7 |
0.0055 |
3.8 |
5.0 |
7.5 |
11.8 |
15.1 |
|
325 |
1 |
57 |
9 |
0.0197 |
6.7 |
9.0 |
13.4 |
20.1 |
26.9 |
|
|
2 |
56 |
9 |
0.0097 |
6.6 |
8.8 |
12.3 |
19.8 |
26.4 |
|
|
4 |
40 |
9 |
0.0035 |
4.7 |
6.3 |
9.4 |
14.1 |
18.8 |
|
400 |
1 |
98 |
12 |
0.0039 |
11.5 |
15.4 |
23.1 |
34.6 |
46.2 |
|
|
2 |
94 |
11 |
0.0163 |
11.1 |
14.8 |
22.1 |
33.2 |
44.3 |
|
|
4 |
76 |
11 |
0.0066 |
9.0 |
11.9 |
17.9 |
26.9 |
35.8 |
|
450 |
1 |
135 |
13 |
0.0468 |
15.9 |
21.2 |
31.8 |
47.7 |
63.6 |
|
|
2 |
126 |
12 |
0.0218 |
14.8 |
19.8 |
29.7 |
44.5 |
59.4 |
|
|
4 |
106 |
12 |
0.0092 |
12.5 |
16.7 |
25.0 |
37.5 |
50.0 |
|
500 |
1 |
174 |
14 |
0.0603 |
|
27.3 |
41.0 |
61.5 |
82.0 |
|
|
2 |
164 |
15 |
0.0284 |
|
25.8 |
38.6 |
58.0 |
77.3 |
|
|
4 |
144 |
15 |
0.0125 |
|
22.6 |
33.9 |
50.9 |
67.9 |
Technical Data(Heat transfer tube Φ20)
|
Nominal diameter(mm) |
Number of tube passes |
Number of tube |
Center row tube number |
Tube side flow area |
Heat transfer area |
||||
|
|
|
|
|
|
1500 |
2000 |
3000 |
4500 |
6000 |
|
159 |
1 |
15 |
5 |
0.0030 |
1.4 |
1.9 |
2.8 |
|
|
|
219 |
1 |
33 |
7 |
0.0066 |
3.1 |
4.1 |
6.2 |
|
|
|
273 |
1 |
65 |
9 |
0.0131 |
6.1 |
8.2 |
12.3 |
18.4 |
24.5 |
|
|
2 |
56 |
8 |
0.0056 |
5.3 |
7.0 |
10.6 |
15.8 |
21.1 |
|
325 |
1 |
99 |
11 |
0.0199 |
9.3 |
12.4 |
18.7 |
28.0 |
37.3 |
|
|
2 |
88 |
10 |
0.0088 |
8.3 |
11.1 |
16.6 |
24.9 |
33.2 |
|
|
4 |
68 |
11 |
0.0034 |
6.4 |
8.5 |
12.8 |
19.2 |
25.6 |
|
400 |
1 |
174 |
14 |
0.0350 |
16.4 |
21.9 |
32.8 |
49.2 |
65.6 |
|
|
2 |
164 |
15 |
0.0165 |
15.5 |
20.6 |
30.9 |
46.4 |
61.8 |
|
|
4 |
146 |
14 |
0.0073 |
13.8 |
18.3 |
27.5 |
41.3 |
55.0 |
|
450 |
1 |
220 |
17 |
0.0477 |
22.3 |
29.8 |
44.7 |
67.0 |
89.3 |
|
|
2 |
220 |
16 |
0..0221 |
20.7 |
27.6 |
41.5 |
62.2 |
82.9 |
|
|
4 |
200 |
16 |
0.0101 |
18.8 |
25.1 |
37.7 |
56.5 |
75.4 |
|
500 |
1 |
275 |
19 |
0.0553 |
|
34.6 |
51.8 |
77.8 |
103.7 |
|
|
2 |
256 |
18 |
0.0257 |
|
32.2 |
48.3 |
72.4 |
96.5 |
|
|
4 |
222 |
18 |
0.0112 |
|
27.9 |
41.8 |
62.8 |
83.7 |
Technical Data(Heat transfer tube Φ25)
|
Nominal diameter(mm) |
Number of tube passes |
Number of tube |
Center row tube number |
Tube side flow area |
Heat transfer area |
||||
|
|
|
|
|
|
1500 |
2000 |
3000 |
4500 |
6000 |
|
159 |
1 |
11 |
3 |
0.0038 |
1.3 |
1.7 |
2.6 |
|
|
|
219 |
1 |
25 |
5 |
0.0087 |
2.9 |
3.9 |
5.9 |
|
|
|
273 |
1 |
38 |
6 |
0.0132 |
4.5 |
6.0 |
9.0 |
13.4 |
17.9 |
|
|
2 |
32 |
7 |
0.0055 |
3.8 |
5.0 |
7.5 |
11.8 |
15.1 |
|
325 |
1 |
57 |
9 |
0.0197 |
6.7 |
9.0 |
13.4 |
20.1 |
26.9 |
|
|
2 |
56 |
9 |
0.0097 |
6.6 |
8.8 |
12.3 |
19.8 |
26.4 |
|
|
4 |
40 |
9 |
0.0035 |
4.7 |
6.3 |
9.4 |
14.1 |
18.8 |
|
400 |
1 |
98 |
12 |
0.0039 |
11.5 |
15.4 |
23.1 |
34.6 |
46.2 |
|
|
2 |
94 |
11 |
0.0163 |
11.1 |
14.8 |
22.1 |
33.2 |
44.3 |
|
|
4 |
76 |
11 |
0.0066 |
9.0 |
11.9 |
17.9 |
26.9 |
35.8 |
|
450 |
1 |
135 |
13 |
0.0468 |
15.9 |
21.2 |
31.8 |
47.7 |
63.6 |
|
|
2 |
126 |
12 |
0.0218 |
14.8 |
19.8 |
29.7 |
44.5 |
59.4 |
|
|
4 |
106 |
12 |
0.0092 |
12.5 |
16.7 |
25.0 |
37.5 |
50.0 |
|
500 |
1 |
174 |
14 |
0.0603 |
|
27.3 |
41.0 |
61.5 |
82.0 |
|
|
2 |
164 |
15 |
0.0284 |
|
25.8 |
38.6 |
58.0 |
77.3 |
|
|
4 |
144 |
15 |
0.0125 |
|
22.6 |
33.9 |
50.9 |
67.9 |

Air Cooled Heat Exchanger is a highly efficient cooling device that dissipates heat from industrial fluids (e.g., water, glycol, oil, or chemicals) into surrounding ambient air via extended finned coil tubes and axial cooling fans, it cuts reliance o...

Tube Bundle Heat Exchanger is a highly efficient thermal transfer device that exchanges heat between two separate industrial fluids (e.g., water, glycol, oil, or chemicals) through densely arranged heat-conductive tube bundles and sealed shell chambe...

U-Tube Heat Exchanger is a highly efficient thermal transfer device that exchanges heat between two isolated industrial fluids (e.g., water, glycol, oil, or chemicals) through bendable U-shaped tube bundles and sealed pressure shells, it automaticall...

Shell and Tube Heat Exchangers are designed and manufactured in full compliance with TEMA (Tubular Exchanger Manufacturers Association) standards, ensuring mechanical integrity, high reliability, and long service life. Each exchanger is engineered fo...

Blue Shell and Tube Heat Exchanger is a highly efficient heat transfer device that exchanges heat between two different industrial fluids (e.g., water, glycol, oil or chemical liquids) through internal tube bundles and shell chambers, it delivers sta...

Tube Heat Exchangers are engineered for stable and efficient operation under high temperature and high pressure environments. The design allows for flexible configurations such as fixed tube sheet, floating head, and U-tube bundle types to accommodat...

Floating Head Heat Exchanger is a high-efficiency thermal transfer device that realizes bidirectional heat exchange between industrial fluids (e.g., water, glycol, oil, or chemicals) through precision tube bundles and sealed shell chambers, it compen...

Horizontal Shell and Tube Heat Exchanger is a highly efficient thermal transfer device that conducts heat exchange between two distinct industrial fluids (e.g., water, glycol, oil, or chemicals) through dense tube bundles and a horizontal sealed shel...

Shell and Tube Condenser is a highly efficient heat exchange device that condenses gaseous refrigerants or industrial vapors by transferring heat to cooling media (e.g., water, glycol, or brine) through dense tube bundles and sealed shell chambers, i...

Shell and Tube Evaporator is a highly efficient heat transfer device that absorbs heat from industrial fluids (e.g., water, glycol, oil, or process liquids) to vaporize refrigerants through dense tube bundles and pressure-tight shell chambers, it del...

Shell and Tube Exchanger is a highly efficient thermal transfer device that exchanges heat between two isolated industrial fluids (e.g., water, glycol, oil, or chemical media) through high-precision tube bundles and sealed pressure-resistant shells, ...

Includes fixed tube-sheet, U-tube, floating head types, and more.Shell and Tube Heat Exchangers are highly efficient thermal transfer devices that conduct heat exchange between two separate industrial fluids (e.g., water, glycol, oil, or chemicals) t...

Titanium Steel Shell and Tube Heat Exchanger is a highly efficient thermal transfer device that exchanges heat between two isolated industrial fluids (e.g., seawater, brine, glycol, or corrosive chemicals) through corrosion-resistant titanium tube bu...

Tube and Shell Heat Exchanger is a highly efficient thermal transfer device that realizes heat exchange between two independent industrial fluids (e.g., water, glycol, oil, or chemicals) through dense heat-conductive tube bundles and fully sealed pre...

Air Cooled Heat Exchanger is a highly efficient cooling device that dissipates heat from industrial fluids (e.g., water, glycol, oil, or chemicals) into surrounding ambient air via extended finned coil tubes and axial cooling fans, it cuts reliance o...

Tube Bundle Heat Exchanger is a highly efficient thermal transfer device that exchanges heat between two separate industrial fluids (e.g., water, glycol, oil, or chemicals) through densely arranged heat-conductive tube bundles and sealed shell chambe...

U-Tube Heat Exchanger is a highly efficient thermal transfer device that exchanges heat between two isolated industrial fluids (e.g., water, glycol, oil, or chemicals) through bendable U-shaped tube bundles and sealed pressure shells, it automaticall...

Shell and Tube Heat Exchangers are designed and manufactured in full compliance with TEMA (Tubular Exchanger Manufacturers Association) standards, ensuring mechanical integrity, high reliability, and long service life. Each exchanger is engineered fo...

Blue Shell and Tube Heat Exchanger is a highly efficient heat transfer device that exchanges heat between two different industrial fluids (e.g., water, glycol, oil or chemical liquids) through internal tube bundles and shell chambers, it delivers sta...

Tube Heat Exchangers are engineered for stable and efficient operation under high temperature and high pressure environments. The design allows for flexible configurations such as fixed tube sheet, floating head, and U-tube bundle types to accommodat...

Floating Head Heat Exchanger is a high-efficiency thermal transfer device that realizes bidirectional heat exchange between industrial fluids (e.g., water, glycol, oil, or chemicals) through precision tube bundles and sealed shell chambers, it compen...

Horizontal Shell and Tube Heat Exchanger is a highly efficient thermal transfer device that conducts heat exchange between two distinct industrial fluids (e.g., water, glycol, oil, or chemicals) through dense tube bundles and a horizontal sealed shel...